Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 134
Filtrar
1.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38571291

RESUMO

AIMS: Same-day discharge (SDD) after atrial fibrillation (AF) ablation is an effective means to spare healthcare resources. However, safety remains a concern, and besides structural adaptations, SDD requires more efficient logistics and coordination. Therefore, in this study, we implement a streamlined, nurse-coordinated SDD programme following a standardized protocol. METHODS AND RESULTS: As a dedicated SDD coordinator, a nurse specialized in ambulatory cardiac interventions was in charge of the full SDD protocol, including eligibility, patient flow, in-hospital logistics, patient education, and discharge as well as early post-discharge follow-up by smartphone-based virtual visits. Patients planned for AF ablation were considered eligible if they had a left ventricular ejection fraction (LVEF) ≥35%, with basic support at home and accessibility of the hospital within 60 min also forming a part of the eligibility criteria. A total of 420 consecutive patients were screened by the SDD coordinator, of whom 331 were eligible for SDD. The reasons for exclusion were living remotely (29, 6.9%), lack of support at home (19, 4.5%), or LVEF <35% (17, 4.0%). Of the eligible patients, 300 (91%) were successfully discharged the same day. There were no major post-SDD complications. Rates of unplanned medical attention (19, 6.3%) and 30-day readmission (5, 1.6%) were extremely low and driven by femoral access-site complications. These were significantly reduced upon the introduction of compulsory ultrasound-guided punctures after the initial 150 SDD patients (P = 0.0145). Standardized SDD coordination resulted in efficient workflows and reduced the total workload of the medical staff. CONCLUSION: Same-day discharge after AF ablation following a nurse-coordinated standardized protocol is safe and efficient. The concept of ambulatory cardiac intervention nurses functioning as dedicated coordinators may be key in the future transition of hospitals to SDD. Ultrasound-guided femoral puncture virtually eliminated relevant femoral access-site complications in our cohort and should therefore be a prerequisite for SDD.


Assuntos
Fibrilação Atrial , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Alta do Paciente , Volume Sistólico , Assistência ao Convalescente , Função Ventricular Esquerda , Estudos Retrospectivos , Resultado do Tratamento
2.
Heart Rhythm ; 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38636930

RESUMO

BACKGROUND: Atrial arrhythmogenic substrate is a key determinant of atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI), and reduced conduction-velocities have been linked to adverse outcome. However, a non-invasive method to assess such electrophysiological substrate is not available to date. OBJECTIVE: This study aimed to non-invasively assess regional conduction-velocities and their association with arrhythmia-free survival following PVI. METHODS: 52 consecutive patients scheduled for AF ablation (PVI-only) and 19 healthy controls were prospectively included and received electrocardiographic imaging (ECGi) to non-invasively determine regional atrial conduction-velocities in sinus rhythm. A novel ECGi technology obviating the need of additional CT- or CMR-imaging was applied and validated using invasive mapping. RESULTS: Mean ECGi-determined atrial conduction-velocities were significantly lower in AF-patients than in healthy controls (1.45±0.15 versus 1.64±0.15m/s; p<0.0001). Differences were particularly pronounced in a regional analysis considering only the segment with the lowest average conduction-velocity in each patient (0.8±0.22 versus 1.08±0.26m/s; p<0.0001). This average conduction velocity of the "slowest" segment was independently associated with arrhythmia recurrence and better discriminated between PVI-responders and non-responders than previously proposed predictors including left atrial size or late-gadolinium-enhancement (MRI). Patients without slow-conduction areas (mean conduction-velocity <0.78m/s) showed significantly higher 12-months arrhythmia-free survival than those with one or more slow-conduction areas (88.9% versus 48.0%, p=0.002). CONCLUSIONS: This is the first study to investigate regional atrial conduction velocities non-invasively. The absence of ECGi-determined slow-conduction areas well discriminates PVI-responders from non-responders. Such non-invasive assessment of electrical arrhythmogenic substrate may guide treatment strategies and be a step towards personalised AF therapy.

3.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38591838

RESUMO

AIMS: Recent trial data demonstrate beneficial effects of active rhythm management in patients with atrial fibrillation (AF) and support the concept that a low arrhythmia burden is associated with a low risk of AF-related complications. The aim of this document is to summarize the key outcomes of the 9th AFNET/EHRA Consensus Conference of the Atrial Fibrillation NETwork (AFNET) and the European Heart Rhythm Association (EHRA). METHODS AND RESULTS: Eighty-three international experts met in Münster for 2 days in September 2023. Key findings are as follows: (i) Active rhythm management should be part of the default initial treatment for all suitable patients with AF. (ii) Patients with device-detected AF have a low burden of AF and a low risk of stroke. Anticoagulation prevents some strokes and also increases major but non-lethal bleeding. (iii) More research is needed to improve stroke risk prediction in patients with AF, especially in those with a low AF burden. Biomolecules, genetics, and imaging can support this. (iv) The presence of AF should trigger systematic workup and comprehensive treatment of concomitant cardiovascular conditions. (v) Machine learning algorithms have been used to improve detection or likely development of AF. Cooperation between clinicians and data scientists is needed to leverage the potential of data science applications for patients with AF. CONCLUSIONS: Patients with AF and a low arrhythmia burden have a lower risk of stroke and other cardiovascular events than those with a high arrhythmia burden. Combining active rhythm control, anticoagulation, rate control, and therapy of concomitant cardiovascular conditions can improve the lives of patients with AF.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Risco , Hemorragia , Anticoagulantes/uso terapêutico
5.
Int J Mol Sci ; 25(3)2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38338818

RESUMO

TRPV4 channels, which respond to mechanical activation by permeating Ca2+ into the cell, may play a pivotal role in cardiac remodeling during cardiac overload. Our study aimed to investigate TRPV4 involvement in pathological and physiological remodeling through Ca2+-dependent signaling. TRPV4 expression was assessed in heart failure (HF) models, induced by isoproterenol infusion or transverse aortic constriction, and in exercise-induced adaptive remodeling models. The impact of genetic TRPV4 inhibition on HF was studied by echocardiography, histology, gene and protein analysis, arrhythmia inducibility, Ca2+ dynamics, calcineurin (CN) activity, and NFAT nuclear translocation. TRPV4 expression exclusively increased in HF models, strongly correlating with fibrosis. Isoproterenol-administered transgenic TRPV4-/- mice did not exhibit HF features. Cardiac fibroblasts (CFb) from TRPV4+/+ animals, compared to TRPV4-/-, displayed significant TRPV4 overexpression, elevated Ca2+ influx, and enhanced CN/NFATc3 pathway activation. TRPC6 expression paralleled that of TRPV4 in all models, with no increase in TRPV4-/- mice. In cultured CFb, the activation of TRPV4 by GSK1016790A increased TRPC6 expression, which led to enhanced CN/NFATc3 activation through synergistic action of both channels. In conclusion, TRPV4 channels contribute to pathological remodeling by promoting fibrosis and inducing TRPC6 upregulation through the activation of Ca2+-dependent CN/NFATc3 signaling. These results pose TRPV4 as a primary mediator of the pathological response.


Assuntos
Calcineurina , Insuficiência Cardíaca , Canais de Cátion TRPV , Remodelação Ventricular , Animais , Camundongos , Calcineurina/metabolismo , Células Cultivadas , Fibrose , Insuficiência Cardíaca/metabolismo , Isoproterenol , Camundongos Transgênicos , Miócitos Cardíacos/metabolismo , Fatores de Transcrição NFATC/genética , Fatores de Transcrição NFATC/metabolismo , Canal de Cátion TRPC6/genética , Canal de Cátion TRPC6/metabolismo , Canais de Cátion TRPV/genética , Canais de Cátion TRPV/metabolismo , Remodelação Ventricular/genética
6.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38262674

RESUMO

AIMS: Non-invasive myocardial scar characterization with cardiac magnetic resonance (CMR) has been shown to accurately identify conduction channels and can be an important aid for ventricular tachycardia (VT) ablation. A new mapping method based on targeting deceleration zones (DZs) has become one of the most commonly used strategies for VT ablation procedures. The aim of the study was to analyse the capability of CMR to identify DZs and to find predictors of arrhythmogenicity in CMR channels. METHODS AND RESULTS: Forty-four consecutive patients with structural heart disease and VT undergoing ablation after CMR at a single centre (October 2018 to July 2021) were included (mean age, 64.8 ± 11.6 years; 95.5% male; 70.5% with ischaemic heart disease; a mean ejection fraction of 32.3 ± 7.8%). The characteristics of CMR channels were analysed, and correlations with DZs detected during isochronal late activation mapping in both baseline maps and remaps were determined. Overall, 109 automatically detected CMR channels were analysed (2.48 ± 1.15 per patient; length, 57.91 ± 63.07 mm; conducting channel mass, 2.06 ± 2.67 g; protectedness, 21.44 ± 25.39 mm). Overall, 76.1% of CMR channels were associated with a DZ. A univariate analysis showed that channels associated with DZs were longer [67.81 ± 68.45 vs. 26.31 ± 21.25 mm, odds ratio (OR) 1.03, P = 0.010], with a higher border zone (BZ) mass (2.41 ± 2.91 vs. 0.87 ± 0.86 g, OR 2.46, P = 0.011) and greater protectedness (24.97 ± 27.72 vs. 10.19 ± 9.52 mm, OR 1.08, P = 0.021). CONCLUSION: Non-invasive detection of targets for VT ablation is possible with CMR. Deceleration zones found during electroanatomical mapping accurately correlate with CMR channels, especially those with increased length, BZ mass, and protectedness.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia , Frequência Cardíaca/fisiologia , Arritmias Cardíacas , Cicatriz/patologia , Ablação por Cateter/métodos
7.
Medicina (Kaunas) ; 60(1)2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38256411

RESUMO

Background and Objectives: Left atrial (LA) remodelling and dilatation predicts atrial fibrillation (AF) recurrences after catheter ablation. However, whether right atrial (RA) remodelling and dilatation predicts AF recurrences after ablation has not been fully evaluated. Materials and Methods: This is an observational study of 85 consecutive patients (aged 57 ± 9 years; 70 [82%] men) who underwent cardiac magnetic resonance before first catheter ablation for AF (40 [47.1%] persistent AF). Four-chamber cine-sequence was selected to measure LA and RA area, and ventricular end-systolic image phase to obtain atrial 3D volumes. The effect of different variables on event-free survival was investigated using the Cox proportional hazards model. Results: In patients with persistent AF, combined LA and RA area indexed to body surface area (AILA + RA) predicted AF recurrences (HR = 1.08, 95% CI 1.00-1.17, p = 0.048). An AILA + RA cut-off value of 26.7 cm2/m2 had 72% sensitivity and 73% specificity for predicting recurrences in patients with persistent AF. In this group, 65% of patients with AILA + RA > 26.7 cm2/m2 experienced AF recurrence within 2 years of follow-up (median follow-up 11 months), compared to 25% of patients with AILA + RA ≤ 26.7 cm2/m2 (HR 4.28, 95% CI 1.50-12.22; p = 0.007). Indices of LA and RA dilatation did not predict AF recurrences in patients with paroxysmal AF. Atrial 3D volumes did not predict AF recurrences after ablation. Conclusions: In this pilot study, the simple measurement of AILA + RA may predict recurrences after ablation of persistent AF, and may outperform measurements of atrial volumes. In paroxysmal AF, atrial dilatation did not predict recurrences. Further studies on the role of RA and LA remodelling are needed.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Masculino , Humanos , Feminino , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Projetos Piloto , Átrios do Coração/diagnóstico por imagem , Ventrículos do Coração
8.
Eur Heart J Cardiovasc Imaging ; 25(2): 188-198, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-37819047

RESUMO

AIMS: Conducting channels (CCs) detected by late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) are related to ventricular tachycardia (VT). The aim of this work was to study the ability of post-ablation LGE-CMR to evaluate ablation lesions. METHODS AND RESULTS: This is a prospective study of consecutive patients referred for a scar-related VT ablation. LGE-CMR was performed 6-12 months prior to ablation and 3-6 months after ablation. Scar characteristics of pre- and post-ablation LGE-CMR were compared. During the study period (March 2019-April 2021), 61 consecutive patients underwent scar-related VT ablation after LGE-CMR. Overall, 12 patients were excluded (4 had poor-quality LGE-CMR, 2 died before post-ablation LGE-CMR, and 6 underwent post-ablation LGE-CMR 12 months after ablation). Finally, 49 patients (age: 65.5 ± 9.8 years, 97.9% male, left ventricular ejection fraction: 34.8 ± 10.4%, 87.7% ischaemic cardiomyopathy) were included. Post-ablation LGE-CMR showed a decrease in the number (3.34 ± 1.03 vs. 1.6 ± 0.2; P < 0.0001) and mass (8.45 ± 1.3 vs. 3.5 ± 0.6 g; P < 0.001) of CCs. Arrhythmogenic CCs disappeared in 74.4% of patients. Dark core was detected in 75.5% of patients, and its presence was not related to CC reduction (52.2 ± 7.4% vs. 40.8 ± 10.6%, P = 0.57). VT recurrence after one year follow-up was 16.3%. The presence of two or more channels in the post-ablation LGE-CMR was a predictor of VT recurrence (31.82% vs. 0%, P = 0.0038) with a sensibility of 100% and specificity of 61% (area under the curve 0.82). In the same line, a reduction of CCs < 55% had sensibility of 100% and specificity of 61% (area under the curve 0.83) to predict VT recurrence. CONCLUSION: Post-ablation LGE-CMR is feasible, and a reduction in the number of CCs is related with lower risk of VT recurrence. The dark core was not present in all patients. A decrease in VT substrate was also observed in patients without a dark core area in the post-ablation LGE-CMR.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Miocárdio/patologia , Meios de Contraste , Imagem Cinética por Ressonância Magnética/métodos , Cicatriz/patologia , Estudos Prospectivos , Gadolínio , Imageamento por Ressonância Magnética/métodos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/patologia , Espectroscopia de Ressonância Magnética
10.
J Am Heart Assoc ; : e031220, 2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-37982389

RESUMO

BACKGROUND: Atrial cardiomyopathy (atCM) is an emerging prognostic factor in cardiovascular disease. Fibrotic remodeling, cardiomyocyte hypertrophy, and capillary density are hallmarks of atCM. The contribution of etiological factors and atrial fibrillation (AF) to the development of differential atCM phenotypes has not been quantified. This study aimed to evaluate the association between histological features of atCM and the clinical phenotype. METHODS AND RESULTS: We examined left atrial (LA, n=95) and right atrial (RA, n=76) appendages from a European cohort of patients undergoing cardiac surgery. Quantification of histological atCM features was performed following wheat germ agglutinin/CD31/vimentin staining. The contributions of AF, heart failure, sex, and age to histological characteristics were determined with multiple linear regression models. Persistent AF was associated with increased endomysial fibrosis (LA: +1.13±0.47 µm, P=0.038; RA: +0.94±0.38 µm, P=0.041), whereas total extracellular matrix content was not. Men had larger cardiomyocytes (LA: +1.92±0.72 µm, P<0.001), while women had more endomysial fibrosis (LA: +0.99±0.56 µm, P=0.003). Patients with heart failure showed more endomysial fibrosis (LA: +1.85±0.48 µm, P<0.001) and extracellular matrix content (LA: +3.07±1.29%, P=0.016), and a higher capillary density (LA: +0.13±0.06, P=0.007) and size (LA: +0.46±0.22 µm, P=0.044). Fuzzy k-means clustering of histological features identified 2 subtypes of atCM: 1 characterized by enhanced endomysial fibrosis (LA: +3.17 µm, P<0.001; RA: +2.86 µm, P<0.001), extracellular matrix content (LA: +3.53%, P<0.001; RA: +6.40%, P<0.001) and fibroblast density (LA: +4.38%, P<0.001), and 1 characterized by cardiomyocyte hypertrophy (LA: +1.16 µm, P=0.008; RA: +2.58 µm, P<0.001). Patients with fibrotic atCM were more frequently female (LA: odds ratio [OR], 1.33, P=0.002; RA: OR, 1.54, P=0.004), with persistent AF (LA: OR, 1.22, P=0.036) or heart failure (LA: OR, 1.62, P<0.001). Hypertrophic features were more common in men (LA: OR=1.33, P=0.002; RA: OR, 1.54, P=0.004). CONCLUSIONS: Fibrotic atCM is associated with female sex, persistent AF, and heart failure, while hypertrophic features are more common in men.

11.
Sci Rep ; 13(1): 16743, 2023 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-37798357

RESUMO

Early detection of atrial fibrillation (AF) enables initiation of anticoagulation and early rhythm control therapy to reduce stroke, cardiovascular death, and heart failure. In a cross-sectional, observational study, we aimed to identify a combination of circulating biomolecules reflecting different biological processes to detect prevalent AF in patients with cardiovascular conditions presenting to hospital. Twelve biomarkers identified by reviewing literature and patents were quantified on a high-precision, high-throughput platform in 1485 consecutive patients with cardiovascular conditions (median age 69 years [Q1, Q3 60, 78]; 60% male). Patients had either known AF (45%) or AF ruled out by 7-day ECG-monitoring. Logistic regression with backward elimination and a neural network approach considering 7 key clinical characteristics and 12 biomarker concentrations were applied to a randomly sampled discovery cohort (n = 933) and validated in the remaining patients (n = 552). In addition to age, sex, and body mass index (BMI), BMP10, ANGPT2, and FGF23 identified patients with prevalent AF (AUC 0.743 [95% CI 0.712, 0.775]). These circulating biomolecules represent distinct pathways associated with atrial cardiomyopathy and AF. Neural networks identified the same variables as the regression-based approach. The validation using regression yielded an AUC of 0.719 (95% CI 0.677, 0.762), corroborated using deep neural networks (AUC 0.784 [95% CI 0.745, 0.822]). Age, sex, BMI and three circulating biomolecules (BMP10, ANGPT2, FGF23) are associated with prevalent AF in unselected patients presenting to hospital. Findings should be externally validated. Results suggest that age and different disease processes approximated by these three biomolecules contribute to AF in patients. Our findings have the potential to improve screening programs for AF after external validation.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Masculino , Idoso , Feminino , Angiopoietina-2 , Estudos Transversais , Biomarcadores , Acidente Vascular Cerebral/complicações , Fatores de Risco , Proteínas Morfogenéticas Ósseas/uso terapêutico
12.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37751383

RESUMO

AIMS: Recurrence of arrhythmia after catheter ablation of atrial fibrillation (AF) in the form of atypical atrial flutter (AFL) is common among a significant number of patients and often requires redo ablation with limited success rates. Identifying patients at high risk of AFL after AF ablation could aid in patient selection and personalized ablation approach. The study aims to assess the relationship between pre-existing atrial cardiomyopathy and the occurrence of AFL following AF ablation. METHODS AND RESULTS: We analysed a cohort of 1007 consecutive AF patients who underwent catheter ablation and were included in a prospective registry. Patients who did not have baseline cardiac magnetic resonance imaging and late gadolinium enhancement (LGE-CMR) or did not experience any recurrences were excluded. A total of 166 patients were included gathering 56 patients who underwent re-ablation due to AFL recurrences and 110 patients who underwent re-ablation due to AF recurrences (P = 0.11). A multiparametric assessment of atrial cardiomyopathy was based on basal LGE-CMR, including left atrial (LA) volume, LA sphericity, and global and segmental LA fibrosis using semiautomated post-processing software. Out of the initial cohort of 1007 patients, AFL and AF occurred in 56 and 110 patients, respectively. An age higher than 65 [odds ratio (OR) = 5.6, 95% confidence interval (CI): 2.2-14.4], the number of previous ablations (OR = 3.0, 95% CI: 1.2-7.8), and the management of ablation lines in the index procedure (OR = 2.5, 95% CI: 1.0-6.3) were independently associated with AFL occurrence. Furthermore, several characteristics assessed by LGE-CMR were identified as independent predictors of AFL recurrence after the index ablation for AF, such as enhanced LA sphericity (OR = 1.3, 95% CI: 1.1-1.6), LA global fibrosis (OR = 1.03, 95% CI: 1.01-1.07), and increased fibrosis in the lateral wall (OR = 1.03, 95% CI: 1.01-1.04). CONCLUSION: Advanced atrial cardiomyopathy assessed by LGE-CMR, such as increased LA sphericity, global LA fibrosis, and fibrosis in the lateral wall, is independently associated with arrhythmia recurrence in the form of AFL following AF ablation.


Assuntos
Fibrilação Atrial , Flutter Atrial , Cardiomiopatias , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/cirurgia , Meios de Contraste , Gadolínio , Imageamento por Ressonância Magnética , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico por imagem , Ablação por Cateter/efeitos adversos , Espectroscopia de Ressonância Magnética
13.
Antioxidants (Basel) ; 12(7)2023 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-37508000

RESUMO

Although the benefits of moderate exercise in patients at high cardiovascular risk are well established, the effects of strenuous exercise remain unknown. We aimed to study the impact of strenuous exercise in a very high cardiovascular risk model. Nephrectomized aged Zucker obese rats were trained at a moderate (MOD) or high (INT) intensity or were kept sedentary (SED) for 10 weeks. Subsequently, echocardiography and ex vivo vascular reactivity assays were performed, and blood, aortas, perivascular adipose tissue (PVAT), and left ventricles (LVs) were harvested. An improved risk profile consisting of decreased body weight and improved response to a glucose tolerance test was noted in the trained groups. Vascular reactivity experiments in the descending thoracic aorta demonstrated increased endothelial NO release in the MOD group but not in the INT group, compared with SED; the free radical scavenger TEMPOL improved endothelial function in INT rats to a similar level as MOD. An imbalance in the expression of oxidative stress-related genes toward a pro-oxidant environment was observed in the PVAT of INT rats. In the heart, INT training promoted eccentric hypertrophy and a mild reduction in ejection fraction. Obesity was associated with LV fibrosis and a transition toward ß-myosin heavy chain and the N2Ba titin isoform. Exercise reverted the myosin imbalance, but only MOD reduced the predominance of the N2Ba titin isoform. In conclusion, moderate exercise yields the most intense cardiovascular benefits in a high-cardiovascular-risk animal model, while intense training partially reverts them.

14.
JACC Clin Electrophysiol ; 9(6): 779-789, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37380313

RESUMO

BACKGROUND: A new functional mapping strategy based on targeting deceleration zones (DZs) has become one of the most commonly used strategies within the armamentarium of substrate-based ablation methods for ventricular tachycardia (VT) in patients with structural heart disease. The classic conduction channels detected by voltage mapping can be accurately determined by cardiac magnetic resonance (CMR). OBJECTIVES: The purpose of this study was to analyze the evolution of DZs during ablation and their correlation with CMR. METHODS: Forty-two consecutive patients with scar-related VT undergoing ablation after CMR in Hospital Clinic (October 2018-December 2020) were included (median age 65.3 ± 11.8 years; 94.7% male; 73.7% ischemic heart disease). Baseline DZs and their evolution in isochronal late activation remaps were analyzed. A comparison between DZs and CMR conducting channels (CMR-CCs) was realized. Patients were prospectively followed for VT recurrence for 1 year. RESULTS: Overall, 95 DZs were analyzed, 93.68% of which were correlated with CMR-CCs: 44.8% located in the middle segment and 55.2% located in the entrance/exit of the channel. Remapping was performed in 91.7% of patients (1 remap: 33.3%, 2 remaps: 55.6%, and 3 remaps: 2.8%). Regarding the evolution of DZs, 72.2% disappeared after the first ablation set, with 14.13% not ablated at the end of the procedure. A total of 32.5% of DZs in remaps correlated with a CMR-CCs already detected, and 17.5% were associated with an unmasked CMR-CCs. One-year VT recurrence was 22.9%. CONCLUSIONS: DZs are highly correlated with CMR-CCs. In addition, remapping can lead to the identification of hidden substrate initially not identified by electroanatomic mapping but detected by CMR.


Assuntos
Desaceleração , Taquicardia Ventricular , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Imageamento por Ressonância Magnética , Coração , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Espectroscopia de Ressonância Magnética
15.
Europace ; 25(6)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37294671

RESUMO

AIMS: To define a stepwise application of left bundle branch pacing (LBBP) criteria that will simplify implantation and guarantee electrical resynchronization. Left bundle branch pacing has emerged as an alternative to biventricular pacing. However, a systematic stepwise criterion to ensure electrical resynchronization is lacking. METHODS AND RESULTS: A cohort of 24 patients from the LEVEL-AT trial (NCT04054895) who received LBBP and had electrocardiographic imaging (ECGI) at 45 days post-implant were included. The usefulness of ECG- and electrogram-based criteria to predict accurate electrical resynchronization with LBBP were analyzed. A two-step approach was developed. The gold standard used to confirm resynchronization was the change in ventricular activation pattern and shortening in left ventricular activation time, assessed by ECGI. Twenty-two (91.6%) patients showed electrical resynchronization on ECGI. All patients fulfilled pre-screwing requisites: lead in septal position in left-oblique projection and W paced morphology in V1. In the first step, presence of either right bundle branch conduction delay pattern (qR or rSR in V1) or left bundle branch capture Plus (QRS ≤120 ms) resulted in 95% sensitivity and 100% specificity to predict LBBP resynchronization, with an accuracy of 95.8%. In the second step, the presence of selective capture (100% specificity, only 41% sensitivity) or a spike-R <80 ms in non-selective capture (100% specificity, sensitivity 46%) ensured 100% accuracy to predict resynchronization with LBBP. CONCLUSION: Stepwise application of ECG and electrogram criteria may provide an accurate assessment of electrical resynchronization with LBBP (Graphical abstract).


Assuntos
Fascículo Atrioventricular , Terapia de Ressincronização Cardíaca , Humanos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial/métodos , Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia/métodos , Sistema de Condução Cardíaco , Resultado do Tratamento
16.
Europace ; 25(3): 989-999, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36607130

RESUMO

AIMS: Heterogeneous tissue channels (HTCs) detected by late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) are related to ventricular arrhythmias, but there are few published data about their arrhythmogenic characteristics. METHODS AND RESULTS: We enrolled 34 consecutive patients with ischaemic and non-ischaemic cardiomyopathy who were referred for ventricular tachycardia (VT) ablation. LGE-CMR was performed prior to ablation, and the HTCs were analyzed. Arrhythmogenic HTCs linked to induced VT were identified during the VT ablation procedure. The characteristics of arrhythmogenic HTCs were compared with those of non-arrhythmogenic HTCs. Three patients were excluded due to low-quality LGE-CMR images. A total of 87 HTCs were identified on LGE-CMR in 31 patients (age:63.8 ± 12.3 years; 96.8% male; left ventricular ejection fraction: 36.1 ± 10.7%). Of the 87 HTCs, only 31 were considered arrhythmogenic because of their relation to a VT isthmus. The HTCs related to a VT isthmus were longer [64.6 ± 49.4 vs. 32.9 ± 26.6 mm; OR: 1.02; 95% CI: (1.01-1.04); P < 0.001] and had greater mass [2.5 ± 2.2 vs. 1.2 ± 1.2 grams; OR: 1.62; 95% CI: (1.18-2.21); P < 0.001], a higher degree of protectedness [26.19 ± 19.2 vs. 10.74 ± 8.4; OR 1.09; 95% CI: (1.04-1.14); P < 0.001], higher transmurality [number of wall layers with CCs: 3.8 ± 2.4 vs. 2.4 ± 2.0; OR: 1.31; 95% CI: (1.07-1.60); P = 0.008] and more ramifications [3.8 ± 2.0 vs. 2.7 ± 1.1; OR: 1.59; 95% CI: (1.15-2.19); P = 0.002] than non-arrhythmogenic HTCs. Multivariate logistic regression analysis revealed that protectedness was the strongest predictor of arrhythmogenicity. CONCLUSION: The protectedness of an HTC identified by LGE-CMR is strongly related to its arrhythmogenicity during VT ablation.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Cicatriz/etiologia , Cicatriz/complicações , Meios de Contraste , Gadolínio , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Miocárdio/patologia , Imageamento por Ressonância Magnética/métodos , Ablação por Cateter/efeitos adversos
17.
Eur Heart J Open ; 3(1): oeac085, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36654964

RESUMO

Aims: With recurrence rates up to 50% after pulmonary vein isolation (PVI) in persistent atrial fibrillation (AF), predictive tools to improve patient selection are needed. Patient selection based on left atrial late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) has been proposed previously (UTAH-classification). However, this approach has not been widely established, in part owed to the lack of standardization of the LGE quantification method. We have recently established a standardized LGE-CMR method enabling reproducible LGE-quantification. Here, the ability of this method to predict outcome after PVI was evaluated. Methods and results: This dual-centre study (n = 219) consists of a prospective derivation cohort (n = 37, all persistent AF) and an external validation cohort (n = 182; 66 persistent, 116 paroxysmal AF). All patients received an LGE-CMR prior to first-time PVI-only ablation. LGE was quantified based on the signal-intensity-ratio relative to the blood pool, applying a uniform LGE-defining threshold of >1.2.  In patients with persistent AF in the derivation cohort, left atrial LGE-extent above a cut-off value of 12% was found to best predict relevant low-voltage substrate (≥2 cm two with <0.5 mV during sinus rhythm) and arrhythmia-free survival 12 months post-PVI. When applied to the external validation cohort, this cut-off value was also predictive of arrhythmia-free survival for both, the total cohort and the subgroup with persistent AF (LGE < 12%: 80% and 76%; LGE > 12%: 55% and 44%; P = 0.007 and P = 0.029, respectively). Conclusion: This dual-centre study established and validated a standardized, reproducible LGE-CMR method discriminating PVI responders from non-responders, which may improve choice of therapeutic approach or ablation strategy for patients with persistent AF.

20.
Europace ; 25(2): 360-365, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36125227

RESUMO

AIMS: Electrical reconnection of pulmonary veins (PVs) is considered an important determinant of recurrent atrial fibrillation (AF) after pulmonary vein isolation (PVI). To date, AF recurrences almost automatically trigger invasive repeat procedures, required to assess PVI durability. With recent technical advances, it is becoming increasingly common to find all PVs isolated in those repeat procedures. Thus, as ablation of extra-PV targets has failed to show benefit in randomized trials, more and more often these highly invasive procedures are performed only to rule out PV reconnection. Here we aim to define the ability of late gadolinium enhancement (LGE)-magnetic resonance imaging (MRI) to rule out PV reconnection non-invasively. METHODS AND RESULTS: This study is based on a prospective registry in which all patients receive an LGE-MRI after AF ablation. Included were all patients that-after an initial PVI and post-ablation LGE-MRI-underwent an invasive repeat procedure, which served as a reference to determine the predictive value of non-invasive lesion assessment by LGE-MRI.: 152 patients and 304 PV pairs were analysed. LGE-MRI predicted electrical PV reconnection with high sensitivity (98.9%) but rather low specificity (55.6%). Of note, LGE lesions without discontinuation ruled out reconnection of the respective PV pair with a negative predictive value of 96.9%, and patients with complete LGE lesion sets encircling all PVs were highly unlikely to show any PV reconnection (negative predictive value: 94.4%). CONCLUSION: LGE-MRI has the potential to guide selection of appropriate candidates and planning of the ablation strategy for repeat procedures and may help to identify patients that will not benefit from a redo-procedure if no ablation of extra-PV targets is intended.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Meios de Contraste , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Gadolínio , Resultado do Tratamento , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Imageamento por Ressonância Magnética , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...